Sensor Electronics SEC 3100 Especificações

Consulte online ou descarregue Especificações para Redes Sensor Electronics SEC 3100. Sensor Electronics SEC 3100 Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 29
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
SEC 3100 Transmitter
Instruction and Operation Manual
Sensor Electronics Corporation
5500 Lincoln Drive
Minneapolis, Minnesota 55436 USA
(952) 938-9486 Fax (952) 938-9617
Web site www.sensorelectronics.com
Part Number 3100-EXP-MANUAL
REV 121107-001
Vista de página 0
1 2 3 4 5 6 ... 28 29

Resumo do Conteúdo

Página 1 - SEC 3100 Transmitter

SEC 3100 Transmitter Instruction and Operation Manual Sensor Electronics Corporation 5500 Lincoln Drive Minneapolis, Minnesota 55436 USA (952

Página 2

Selecting Enter when the SEC 3100 in in normal operating mode will advance to the following display: Selecting Enter will allow the operator to

Página 3 - Table of Contents

Main Menu and Sub Menus Enter Calibration Menu EJECT MEMORY CARD INFO * MAIN MENU * CALIBRATION ALA

Página 4 - I. SPECIFICATIONS

Calibration Menu Enter * CALIBRATION ALARM RELAY Using the Up and Down arrows allows the operator to move the cursor (*) to select

Página 5 - Installation and Startup

To Span the sensor with calibration gas use the Up and Down arrows to select the following display. Apply span gas to the sensor for the

Página 6

Alarm Menu Enter CALIBRATION * ALARM RELAY Enter Select the Alarm Relay (LOW, MID, HI) using the down arrow. Once the cursor

Página 7

Arrow Down Selecting Enter will allow the operator to change the operation of the relay operation from Active HI

Página 8

Relay Menu CALIBRATION ALARM * RELAY Selecting Enter will advance to the following menu. * LOW MID HI Arrow down

Página 9 - ID: 1

Select Enter ON DLY LOW * OFF DLY 0 ENERGIZED EXIT Select Enter ON DLY LOW * OFF DLY

Página 10

Network Menu * NETWORK HIDE Select Enter * ZONE 0 ID ONLINE EXIT Select Enter to change the Zone numbe

Página 11

Hide Menu NETWORK * HIDE NO Using Enter the operator can toggle between Hide YES and Hide NO. The Hide function allows the oper

Página 12

Sensor Electronics Corporation Sensor Electronics Corporation (SEC) designs and manufactures innovative fixed system gas detection quality and ser

Página 13

Time Date Menu SELF TEST * DATE TIME Entering this menu will allow the operator to set the time and date of the SEC 3100 real time

Página 14

Select Enter * EXIT Selecting Enter again will return the SEC 3100 to normal operation.

Página 15

Diagnostics Menu * DIAGNOSTICS REST RELAYS EXIT The Diagnostics Menu will allow the operator to enter the Locator Mode and Toggle

Página 16

Reset Relays Menu DIAGNOSTICS * RESET RELAYS EXIT The Reset Reset relays Menu will allow the operator to reset latched relays. Lat

Página 17

V. FIGURES Figure 1 – Overall Layout Figure 2 – SEC 3100 Wiring Figure 3 – SEC Sensor Separation Kit Figure 4 – Mounting SEC 3100 and SEC Mill

Página 18

LCD Display: Real Time Status Gas Type Gas Concentration Fault Identification Range ID Number Memory Card Status Interactive M

Página 19 - : 1 ID

TB 3 (1) WHITE (DATA/CAL) (2) BLUE OR GREEN (4-20 mA) (3) RED (+24 VDC) (4) BLACK (DC COMMO

Página 20

SENSOR ELECTRONICS CORPORATION 5500 LINCOLN DRIVE MINNEAPOLIS, MINNESOTA 55436 USA (T) 952.938.9486 (F) 952.938.9617 [email protected] F

Página 21 - * EXIT

FIGURE 4 SEC 3100 – SEC Millenium Mounting

Página 22

FIGURE 5 SEC 3100 – SEC 3000 Mounting

Página 23 - EXIT

Table of Contents I. SPECIFICATIONS II. GENERAL DESCRIPTION III. OPERATION Installation and Startup Fault Codes IV. MAGNETIC

Página 24 - V. FIGURES

I. SPECIFICATIONS Model: SEC 3100 Transmitter For use with: SEC Millenium and SEC Signature series infrared sensors and SEC 3000 Toxic and Oxy

Página 25 - ¾ h )

II GENERAL DESCRIPTION CONVENTIONS The following conventions are used in this manual. Warning Statement ! VDC (DC Voltag

Página 26 - FIGURE 2

rise. In addition, if the temperature of the gas is hotter than ambient air or mixed with gases that are lighter than air, it could also rise. •

Página 27 - SEC SENSOR SEPARATION KIT

The 4 to 20 mA output of the SEC 3100 sensor is a non-isolated current source. Current Output and Corresponding Status Curren

Página 28 - FIGURE 4

IV. MAGNETIC SWITCH OPERATION The SEC 3100 has three (3) magnetic switch pickups on the Display PCB. The picture below shows the location of

Página 29 - SEC 3100 – SEC 3000 Mounting

V. MENU OPERATION Inital Power Up Sequence of the SEC 3100 SYSTEM BOOT PROCESS --- WAIT FOR SYNC –- SYSTEM BOOT PROCESS -WAIT FOR